Every battery brochure quotes a cycle rating. Six thousand cycles, ten thousand, sometimes more. None of them tells you what your box on the garage wall will actually hold in year eight.
That's a strange gap, when you think about it. Lab cells get cycled in temperature chambers for years, and the results are public. Real home batteries, the ones bolted next to an inverter and left alone, have almost no published track record at all.
There's one big exception. A team at RWTH Aachen's ISEA institute logged 21 privately owned home storage systems in Germany for up to eight years, at one-second resolution, and ran manual capacity tests on them along the way. The paper came out in Nature Energy in 2024. It's the best answer anyone has to the question homeowners actually ask: how many kWh do I lose each year?
I haven't owned or tested any of these batteries. What I did was read the study, pull the warranty PDFs from Tesla, Enphase and BYD, and build a small model that projects capacity out to 15 years. Here's what it all says.
How Much Capacity Do Home Batteries Lose Per Year?
About 2 to 3 percentage points of usable capacity a year, on average. That's the headline from Figgener and colleagues, and it holds across three chemistries.
The 21 systems fell into three groups. Based on the field capacity tests, the average yearly loss looked like this:
| Group in the study | Chemistry | Systems | Nominal size | Full cycles per year | Average capacity loss |
|---|---|---|---|---|---|
| Small LMO | LMO/NMC blend | 6 | 2.2 kWh | about 250 | 2.1 points per year |
| Medium NMC | NMC | 7 | 8.6 to 11.5 kWh | about 200 | 3.2 points per year |
| Medium LFP | LFP | 8 | 8.1 to 13.8 kWh | about 200 | 2.2 points per year |
Two things jump out. LFP and NMC weren't far apart, and both groups cycled far less than daily. Around 200 equivalent full cycles a year is barely more than half of the 365 that sizing spreadsheets usually assume.
Why so few? The authors saw strong seasons. Regular full cycles happened in spring and autumn, fewer in summer, and almost none in winter, when a German roof can't fill the pack. In summer some systems simply weren't discharged much, because the house didn't need it.
The spread matters as much as the average. Some test results dipped slightly below 80% of nominal capacity after just 4.5 years. The first clear end-of-life cases, defined as 80%, showed up after about seven. Others still looked healthy at the same age. The paper's conclusion is that systems with faster fade reach 80% after five to seven years, while warranty periods "can be reached in most cases by including ageing reserves."
That last phrase is doing a lot of work, and I'll come back to it.
One caveat sits on top of everything. These were first-generation products, measured from 2015 to 2022. Newer packs may do better. Nobody has published eight years of field data on a 2024 battery yet, because 2032 hasn't happened.
Why Doesn't Field Fade Match Lab Cycle Ratings?
Because cycles aren't the main thing wearing a home battery out. Time is.
Run the numbers on the LFP group. At about 200 cycles a year, seven years is roughly 1,400 full cycles. Over those seven years, 2.2 points a year adds up to about 15 points of lost capacity.
Now compare that with lab cycling. Sandia's multi-year study of commercial cells, which I covered in our battery sizing guide, found LFP cells taking 2,500 to 9,000 full cycles to reach 80%. That's 20 points over 2,500 to 9,000 cycles, or between 0.22 and 0.8 points per 100 cycles. Multiply by 1,400 cycles and cycling alone would explain 3 to 11 points.
The field batteries lost about 15.
So, by my arithmetic, roughly 30 to 80 percent of the measured fade isn't cycling at all. It's calendar ageing: the slow chemistry that runs whether the pack is working or not, and runs faster when it's warm and when it's held full. Per cycle, the field LFP systems faded 1.4 to 5 times faster than the lab cells. That's not a flaw in either study. The lab measured one stress, the house delivered two.
Calendar Ageing or Cycling: Which One Dominates at Home?
For an ordinary solar self-consumption battery, calendar ageing. Here's where each one takes over.
Calendar ageing dominates when the battery sits full. The paper's example day shows the pattern: empty at dawn, full by noon, held at a high state of charge all afternoon, drained overnight. That's a summer day for most solar batteries, repeated a hundred times a year. ACCURE, the battery analytics firm where Figgener now works, puts it bluntly: batteries age fast at high states of charge, and a forecast-based strategy that delays charging until about noon keeps the average lower. Calendar studies such as the 2018 TUM work on a commercial LFP cell, stored at 17 combinations of temperature and charge level, model the loss as a function of both.
Heat adds to it. A pack in a south-facing garage that hits the high 30s C every afternoon ages faster than the same pack in a cool basement, cycles or no cycles. Cold is a different problem: it mostly blocks charging rather than destroying capacity, which our cold weather limits by maker covers in detail.
Cycling takes over when you work the battery hard. Two full cycles a day for wholesale arbitrage, frequent virtual power plant dispatch, or a big EV charged from the pack every night. At 500 to 700 cycles a year, the cycle term grows until it rivals the calendar term. If that's your plan, the economics in our home battery arbitrage model matter more than anything here.
Backup-only batteries are the extreme calendar case. Held at 100% for months, rarely discharged, they're doing almost nothing and ageing anyway. If your inverter lets you set a backup reserve below full, a lower setting outside storm season is the cheapest thing you can do for the pack's lifespan.
So what can a homeowner change? Not much, honestly, and that's fine. Charging later in the day, avoiding a hot room, and not pinning the battery at 100% for backup when there's no storm forecast. The rest is chemistry you bought on day one.
What Do Home Battery Warranties Actually Promise?
A floor, a term, and sometimes a throughput cap. Each maker words it differently, and the differences matter. I read the PDFs, not the brochures:
| Battery | Term | Capacity floor | Cap that can end it early |
|---|---|---|---|
| Tesla Powerwall 3 (USA, rev. 2.6) | 10 years | 70% of 13.5 kWh at year 10 | Unlimited cycles for solar self-consumption, time-of-use and backup; 37.8 MWh for other uses, measured at AC output |
| Enphase IQ Battery 5P (AU/NZ warranty, June 2024) | 15 years or 6,000 discharged cycles, earlier wins | 70% of nameplate at year 10, 60% at year 15 | 6,000 cycles |
| BYD Battery-Box Premium HVM-US 22.1 (USA, V1.3) | 10 years | 70% of 22.1 kWh usable | 53.87 MWh minimum throughput, whichever comes first |
Enphase's US datasheet states the 5P's warranty as more than 60% capacity for up to 15 years or 6,000 cycles, without the 70% midpoint. Check the warranty for your country and model before relying on either number.
The fine print hides three things worth knowing.
First, the test method. BYD's US warranty is the only one of the three that spells it out: discharge to cutoff, rest ten minutes, charge to full, rest ten minutes, then a constant-current discharge at 10 A while the room sits at 25 to 28 C. The remaining usable energy is the integral of that last discharge. Your app's number isn't that number, and the warranty test is the one that counts.
Second, the strings. Tesla requires the Powerwall to stay connected to the internet and registered for the full ten years; otherwise it promises as little as four. BYD voids coverage for temperatures above 50 C or below -10 C, for operation with a non-certified inverter, and if you don't grant internet access to the performance data after a claim. These aren't exotic conditions. A dead router for a summer could matter.
Third, the throughput cap, which can beat the calendar. BYD's 53.87 MWh on a 22.1 kWh pack equals about 2,438 full cycles. The chart above runs that against fade. At the 200 cycles a year the field study measured, the cap arrives after the 10-year term, at about year 14.6. At 250 cycles it lands around year 11. Cycle the pack fully every day and the warranty ends at about year 7.3, before the clock does. Oddly, faster fade pushes the cap later, because a smaller pack puts out fewer kWh per cycle.
If you own the BYD Battery-Box Premium HVS or another regional variant, the throughput table is different, so look up your exact model.
A home battery mostly ages by sitting full, not by working: field LFP systems lost capacity 1.4 to 5 times faster per cycle than lab cells, because the clock never stops.
What Does the Model Project Over 15 Years?
The hero chart at the top comes from a short script, examples/battery-degradation-model/, in this site's repository. It assumes linear fade, which is what the study fitted; the authors saw no clear knee point in eight years, though they note one can't be ruled out. Past year eight, every line is an extrapolation.
Three rates: the measured LFP and NMC averages, plus a 1.5 point "better than field" case that I made up as an optimistic bound. It isn't measured anywhere. I also ran each one with a 5% hidden ageing reserve, meaning the pack ships with 5% more capacity than the label and the battery management system releases it as cells age. That 5% is my assumption; no maker publishes its buffer.
| Fade rate | Reserve | Year 5 | Year 10 | Year 15 | Crosses 70% | Powerwall 3 kWh at year 10 |
|---|---|---|---|---|---|---|
| 1.5 points/yr (assumed) | none | 92.5% | 85.0% | 77.5% | year 20 | 11.5 |
| 2.2 points/yr (field LFP) | none | 89.0% | 78.0% | 67.0% | year 13.6 | 10.5 |
| 3.2 points/yr (field NMC) | none | 84.0% | 68.0% | 52.0% | year 9.4 | 9.2 |
| 2.2 points/yr (field LFP) | 5% | 94.0% | 83.0% | 72.0% | year 15.9 | 11.2 |
| 3.2 points/yr (field NMC) | 5% | 89.0% | 73.0% | 57.0% | year 10.9 | 9.9 |
Read the third row against the Powerwall floor. Seventy percent of 13.5 kWh is 9.45 kWh. A pack fading at the NMC field rate with no reserve sits at 9.2 kWh in year 10, which would be a claim. Give it a 5% reserve and it holds 9.9 kWh and squeaks past.
That's what "ageing reserves" means in practice. The reserve isn't generosity. It's the margin that turns a borderline battery into one that clears its warranty by a few months.
The LFP line is the encouraging one. At 2.2 points a year, a battery has about 78% left at year 10, comfortably over 70%. Enphase's 60% at year 15 is cleared too: the line sits at 67% then. On a 13.5 kWh pack that's 10.5 kWh at year ten instead of 13.5, so plan around the year-10 number when you size for backup, as the sizing guide suggests.
My opinion, for what it's worth: a 15-year warranty is worth more than a cheaper battery with a 10-year one, but only if the 15-year floor sits below the curve you'd expect anyway. At field LFP rates, 60% at year 15 does. The lifespan claim that matters is the one that would trigger a payout, and few of these will.
How Do You Measure Your Own Battery's State of Health?
Don't trust the single "state of health" percentage your app shows. The study's authors point out that battery management systems use calculation schemes nobody outside the maker can see, with known inaccuracies. Measure usable capacity yourself, from the energy data.
The method below is a home version of what the researchers automated, which was integrating energy between a fully charged and a fully discharged state:
- Pick a mild evening. Room temperature near 20 to 25 C, battery at 100% at sunset. Cold shrinks usable capacity temporarily and will read as fake degradation.
- Find a full-to-empty run. Overnight, the battery should drain to its minimum before the sun returns. If it doesn't empty by morning, you can't use that night.
- Read the kWh discharged. Use the 5-minute or 15-minute export, not the daily total. Our guide to reading inverter data shows where that view usually hides.
- Correct for the reserve. If you hold a 20% backup reserve, that run covered 80% of the range. Divide the kWh by 0.8 before going further.
- Divide by the rated usable capacity. The result is your state of health, as a share of nameplate.
- Repeat it every year in the same month. One reading means little. Five readings make a slope.
Expect year one to read below 100%. Most apps log energy on the AC side, after inverter losses; Enphase lists 96% DC and 90% AC round-trip efficiency for the 5P, so a fresh pack can show a few percent short. That's why the baseline is your own first-year number, not the label.
What's a worrying slope? Anything steadier than about 3 points a year, the field NMC average. If you're there by year four or five, start a written record and ask the maker for the warranty test. And if you're unsure whether a dip is the battery or just a dull month, our piece on winter dips versus degradation covers the same trap for panels.
Keep a second log while you're at it: total kWh discharged per year. Divide by usable capacity and you get your equivalent full cycles, which tells you how fast you're spending any throughput cap. Panels are easier, by the way. Our 11-year SunPower case study shows they lose well under 1% a year. Batteries lose several times that, which is why they're the part of a solar system that gets replaced.
What Can't These Numbers Tell You?
Quite a lot, and it's worth being plain about it.
Twenty-one systems is a small sample, all in Germany, all first generation. A garage in Phoenix would almost certainly age faster. Linear fade beyond eight years is an assumption, and lithium cells can hit a knee where loss suddenly speeds up. The study's capacity is normalised to the nominal figure printed on the modules, which isn't always what the warranty measures. And the lab comparison in this article mixes a cell study with system data, so treat my calendar-versus-cycling split as a rough bracket, not a decomposition.
What would change my mind? A large fleet dataset from a current maker, published with the method. The European Union's batteries regulation pushes in that direction by demanding transparent state-of-health estimates, which is exactly why the RWTH team built the method. Until then, this dataset is the floor of what anyone actually knows.
Summary
The best public field data, 21 German home batteries measured for up to eight years, shows usable capacity falling about 2 to 3 percentage points a year: 2.2 for LFP, 3.2 for NMC. Those systems ran only about 200 to 250 full cycles a year, so calendar ageing from time spent charged and warm likely drives most of the loss, not cycling. At the LFP rate a battery keeps about 78% at year 10, above the common 70% warranty floor; at the NMC rate it lands near 68% and relies on the maker's hidden ageing reserve. Check your own pack once a year from a full-to-empty discharge in the same month, and read your warranty for throughput caps, which can end a heavily cycled BYD warranty around year seven.